Flexible Module Combination Function
All sockets and function modules can be flexibly combined together to build out PDU of different functions and different country standards.
Advanced Manufacturing Process
eTON PDU socket modules are fine processed adopting the method of non-spot welded by screw thread terminals. This method perfectly ensure safe and reliable interior electrical conductivity.
Practical Installation Methods
eTON PDU are rich in a full range of product styles, and available at practical PDU product accessories.These features enable Wisdom PDU to be installed in various kinds of standard or non-standard cabinets, and save space.
Abundant Socket Modules
eTON PDU offers different country standards sockets, which enrich worldwide customers' options.
eTON PDU can be classfied into W1 and W2 two series socket series. W1 socket is suitable for being installed in 1U high PDU outer shell, and W2 socket is suitable for being installed in 1.4U high PDU outer shell. "X" means that PDU outer shell can be made according to customer's requirements.
High Quality and Environment Friendly
Production Materials
All eTON PDU socket modules adopt PC/ABS plastic materials, the deformation temperature of which is over 120 C, Fire-retardant characteristic is in compliance with UL94-V0 standard; all the adopted metal connecting slice are made of phosphorus bronze with high elasticity and high wearability; all passive componets adopt safety authentication materials.
Multiple Input Styles
eTON PDU are available at flexible and multiple input styles at: single end input, double ends input, shell-back input and etc.
Strong Voltage Load
The unique processing technology support eTON PDU with reliable and diversified voltage load ranging from the minimum single-way power 2500W to the maximum double-way 8000W, from single-phase power 250VAC to three phase power 380VAC.
Monitoring
|
Total load current
|
Outlet current
|
Total load voltage
|
Outlet on/off status
|
Display
|
System operation status
|
Temperature
|
Humidity
|
Smoke
|
Water logging
|
Door opened or closed
|
Communication
|
TCP/IP
|
Wed
|
SNMP
|
Telnet/SSH
|
System
|
Single user
|
Multiuser operation system
|
Sensor port
|
Temperature/humidity
|
Smoke
|
Water logging
|
Door opened or closed
|
Self-define threshold
|
The limited max. & min. value of total load current
|
The limited max. & min. value of temperature/humidity
|
Automatic alarm
|
Overload occurs
|
The limited value is exceeded
|
Automatic alarm system
|
Running indicator flashes and buzzer rings on NPDU
|
Running indicator flashes and buzzer rings on PC
|
Automatic E-mail sent to administrator
|
Log
|
Log record
|
Users authorization management
|
Different user levels setting
|
Energy consumption
|
Automatically record the energy consumption (kWh)
|
Software system
|
Embedded management software, support OEM
|
|